To use my technical knowledge and work collaboratively in a professional environment for achieving corporate goals and to ascent to the institutional hierarchy with full dedication, integrity and loyalty.
EQUIPMENT MAINTAINED:
• DRUPS 2500kva (Dynamic UPS) - ROLLS ROYCE
• Generator 2000kva - CUMMINS
• Transformer 2500 & 2000kva - TESAR
• UPS System - VERTIV
• PDU - APB
• HV Panel, LV Panel, ATS, SMDB, DB, DC Plant.
• ELV systems like SCADA, BMS and Fire Systems.
• AHU, CRAC, FCU, Fluid Cooler, Fuel system,
RESPONSIBILITY
• Carry out Preventive Maintenance activity for electrical asset & mechanical equipment’s control panels installed in data center.
• Power Provisional, Power up & Redundancy Test activities for the IT Rack.
• Monthly report generation for all customers related to Power & Environmental.
• installation of new equipment, decommissioning of equipment, replacement of faulty equipment.
• Incident Report preparation.
• Develop and maintain method statements, standard operating procedures, emergency response procedures, and preventive maintenance programs.
• Vendor coordination for maintenance as per given SLA
• Coordination activities for new projects within the Data Center.
• Performed troubleshooting and repair for complex electrical equipment.
• Forecast the necessary material requirement for a smooth and continues execution.
• Preparing new drawing, Reviewing drawing & perform necessary modification.
• Handle electrical energy management.
• Ability to come up with viable and comprehensive solutions to most of the electrical problem at site.
• Experience in working on CMM - Maximo (Asset, Inventory & Workorder Management)
• Incident & Emergency Response and 24/7 On call Support.
Analytical and problem-solving skills
Facility monitoring and oversight
Innovative, decision-making, and time management skills
Strong knowledge in Electrical system
Ability to handle project and lead a team
Experience in working with Electrical Controls
Familiarity with the health and safety codes in industrial environment
Strong oral and written communication skills
• UI Path robotic automation - Basic
MS OFFICE, AUTOCAD, VISIO, UI PATH
HV Panel- Denway (Dubai)
Transformer - FT (Abudhabi)
DOB: 24/04/1989
MARITAL STATUS: MARRIED
NATIONALITY: INDIAN
PASSPORT NO: S6660674
Total 12+ years of working experience in Facility Management and Electromechanical Installation & Testing Commissioning.
6+ Year Experienced in DATA CENTER (Uptime TIER-III Gold Certified) Operation & Maintenance.
2+ Year Experienced in DATA CENTER PROJECT (Uptime TIER-III Certified) Electromechanical installation & Testing Commissioning.
Acquainted with guiding Members and proficient in all aspects like Maintenance, Project planning, Execution, Monitoring and Resource balancing skills.
Experienced in construction and technical inspection of all Building services.