SHAHUL HAMEED ABDUL SUKKUR

Dubai,,United Arab Emirates

Summary

Well Experienced Electrical Emergency Maintenance Engineer with focus on ensuring optimal performance and reliability of electrical systems. Skilled in troubleshooting, preventive/ Breakdown maintenance, and implementing safety protocols to minimise downtime. Adept at collaborating with cross-functional teams to address complex technical issues and enhance operational efficiency.

Overview

16
16
years of professional experience
6
6
years of post-secondary education

Work History

Engineer-Emergency maintenance(Substation & Cable)

Dubai Electricity and water Authority
Dubai, UAE
03.2014 - Current
  • Worked as an Electrical Engineer handling emergency maintenance activities in the Medium Voltage (MV) distribution network (33kV, 11kV, and 6.6kV), including substation equipment and power cables.
  • Frequently served as a shift in-charge, coordinating with the Load Dispatch Centre to distribute planned and emergency activities among the concerned group leaders on shift.
  • Manage all planned and unplanned activities occurring during the shifts, ensuring that all exigencies are met. Supervise shift staff and take corrective actions for any non-compliances. Ensure the data integrity of daily reports and maintain accurate documentation.
  • Possess strong knowledge in fault finding, repair, and rectification of various types of HV switchgears used in distribution networks.
  • Strong knowledge of various schematic diagram reviews, including troubleshooting and rectification of 33KV & 11KV switchgear complaints.
  • Extensive experience in pre-locating, pinpointing, and rectifying various types of power cable faults in the 33/11kV MV distribution cable network using SEBA KMT (Vario) and Megger (Centrix 2.0) test vans.
  • Performed VLF testing, cable identification, Spiking and route tracing for the 33/11kV MV cable network as per requirements using test vans and portable testing equipment.
  • Handled emergency breakdown maintenance, including the replacement and rectification of switchgear panels and capacitor bank units during flashovers or failures in primary substations of the MV distribution network.
  • Carried out emergency breakdown maintenance for the replacement and repair of RMUs, transformers, and LVDBs during flashovers or failures in secondary substations of the MV distribution network.
  • NOD Inspection and rectification of Ultrasonic discharge from cable terminations of RMUs & switchgears, Sf6 gas pressure low complaints in RMUs & switchgears and Oil leakage complaint from RMUs & Transformers.
  • Conduct Preventive Maintenance for the replacement of RMU, Transformers & LVDB in Secondary substation network.
  • Conduct pre-commissioning test of 33 & 11kv spare panels for PED commissioning Activity.
  • Conducted preventive maintenance activities for switchgear, MV cables, RMUs, distribution transformers, LVDBs, and capacitor banks in primary and secondary substation networks.
  • Attended and resolved complaints, including troubleshooting and rectifying automated motorized RMUs.
  • Mobilize and connect 11kV and 0.4kV MDGs to the distribution network for supply restoration and load reduction during system occurrences.
  • Prepare and maintain detailed reports of preventive and breakdown maintenance activities for management review.
  • Ensure strict adherence to established work procedures and risk assessments in all daily work activities. Consistently follow safety protocols and operational guidelines to maintain a safe, efficient, and compliant working environment.
  • Assisted in training junior staff, enhancing team efficiency.

Senior Testing & Commissioning Engineer

Jaitech Power Project Pvt LTD
Addis Ababa, Ethiopia
08.2012 - 12.2013


  • Client:- Ethiopian power corporation.

Contractor: IRCON INTERNATIONAL LIMITED.

  • Performed Testing and commissioning of 132/33/15kv Substations, outdoor switchyard and 33/15kv indoor switchgear.
  • 132kV switchyard Equipment's, control & relay Panel Schemes and interlock checks.
  • 132/33/15kv Power Transformer, Trafo Aux. Protection / Tap changer scheme checks, numerical relay testing, programming and logic configuration check up.
  • 33kv &15kv switchgears testing, Protection testing, scheme checkup, interlock checkup and auto-reclosure check for outgoing feeders in indoor switchboards.
  • Coordinate and execute installation work with erection and commissioning Team.

Senior Testing & Commissioning Engineer

Jaitech Power Project Pvt LTD.
chennai, india
06.2009 - 08.2012
  • Projects carried out all over India.
  • Testing & Commissioning of CT, VT, CVT, Lightning Arresters, LAVT, Wave Trap, NGR & NGTR.
  • Testing and commissioning of Various types of numerical protection relays such as Differential Protection, O/C, E/F, O/V, U/V, U/F,O/F, REF, Negative phase sequence, thermal overload, loss of load, unbalance, start/stall protection, no of starts and auxiliary relays such that over voltage/ under voltage, Tripping relay, TCS relay, synchronization and auto change over relay
  • Testing and commissioning of Power Transformer and Distribution Transformer (Oil& Dry) Type up to 46MVA Ratings
  • Testing and commissioning of HT/LT Motors & Generators up to 12MW.
  • High Voltage Testing for Power Cables, Busbars and Bus ducts.
  • Testing and commissioning of Switch yard till 400Kv, HT panels, PMCC, MCC,DCDB& ACDB panels and panel Scheme checking, Interlock checking and Auto Changeover Checking
  • Skilled in scheme checking of up to 400kv switch yards, isolator interlock checking and various protection schemes check up
  • Schematic diagrams modification and editings according to clients request as per standard
  • 400KV Switch yards cable schedules modifications and editing
  • Drafting the single line diagram, schematic diagram by using Autocad.
  • Co-ordinate the cable laying and termination of 11kv-6.6kv-415v and control and metering cables.
  • Communicating and configuration of ABB relays with(pcm600) & GE relays(Enervista setup).
  • Computer knowledge in MS-OFFICE and Auto-cad.
  • Trained junior engineers in commissioning procedures, sharing industry knowledge and expertise.

Education

Bachelor of Technology - Electrical and Electronics Engineering

SASTRA
Thanjavur, India
06.2006 - 04.2009

Diploma of Higher Education - Electrical and Electronics Engineering

Shanmugha polytechnic college
Thanjavur, India
06.2003 - 04.2006

Skills

  • Schematic interpretation
  • Technical troubleshooting
  • Fault finding
  • Electrical systems maintenance
  • Preventive maintenance planning
  • Electrical installations and repairs
  • Critical thinking
  • Safety compliance
  • Efficient time management

Languages

Tamil
Native language
English
Fluent
Hindi
Advanced
Arabic
Beginner
Tamil
Native

Declaration

I hereby declare that all the information given above is authentic to the best of my knowledge and that any misrepresentation by me in this application disqualifies my candidature.

Timeline

Engineer-Emergency maintenance(Substation & Cable)

Dubai Electricity and water Authority
03.2014 - Current

Senior Testing & Commissioning Engineer

Jaitech Power Project Pvt LTD
08.2012 - 12.2013

Senior Testing & Commissioning Engineer

Jaitech Power Project Pvt LTD.
06.2009 - 08.2012

Bachelor of Technology - Electrical and Electronics Engineering

SASTRA
06.2006 - 04.2009

Diploma of Higher Education - Electrical and Electronics Engineering

Shanmugha polytechnic college
06.2003 - 04.2006