·ANDT Engineer, Operations Supervisor with 11 years of field experience in inspections in major Refineries, offshore, Pipelines In-service and Construction projects.
· B.Tech in Electronics and Communication Engineering from JNTUK, KAKINADA.
· PCN Level II (PCN No. 345560) in Ultrasonic testing, Phased Array Ultrasonic Testing, Time of Flight Diffraction
· CSWIP LRUT Level II and Level I certified by TWI, London.
· ASNT NDT Level II in Radiographic Testing, Magnetic Particle Testing, Liquid Penetrant Testing Ultrasonic Testing, Eddy Current Testing.
· CSWIP LRUT Level II and Level I certified by TWI, London.
· PCN Level II In UT, PAUT, TOFD Certified by BINDT, PCN Number - 345560
· ASNT Level II in RT, PT, MT, VT, UT, ET
· Employer NDT Level II as per SNT-TC-1A in Radiographic Testing, Magnetic Particle Testing, Liquid Penetrant Testing Ultrasonic Testing, Eddy Current Testing (Tube & Surface), Remote Field Testing, Near Field Testing, Phased Array Ultrasonic Testing and Time of Flight Diffraction.
· Qualified LRUT/ECT/IRIS/RFET/NFET through M/s. RIL, Jamnagar
· Qualified LRUT/ UT/ PAUT/ ECT/IRIS/RFET/NFET through M/S Singapore Refinery Company (SRC) & Chevron.
· Qualified PAUT & ECT/RFT/IRIS through M/S Exxon mobile Singapore.
· Qualified PAUT, TFM-FMC, LRUT/ECT/IRIS/RFET/NFET through M/S Petro Vietnam
· Qualified PAUT, TFM-FMC, LRUT/ECT/IRIS/RFET/NFET through M/S NSRCP Vietnam
· Qualified TFM-FMC through M/S Dhiraj Heavy Equipment's Private Limited
· Qualified PAUT/TOFD/CWUT through M/S Yara Fertilisers India Pvt Ltd
· Qualified PAUT/TOFD/LRUT/AUT-HIC through M/S ADNOC UAE
· AUT HIC (Hydrogen Induced Crack detection) on vessels and columns for M/S ADNOC Das Island offshore.
· PAUT / TOFD (Hydrogen Induced Crack detection) on vessels and columns for M/S ADNOC Das Island offshore.
· LRUT-Inspection of plant piping & Jetty pipeline and piles for M/s ADNOC Ruwais
· PAUT/TOFD/CWUT Inspection on Vassal for M/S ADNOC Ruwais
· PAUT/TOFD/CWUT Inspection on Ammonia Convertor Vassal for M/S Yara Fertilisers India Pvt Ltd
· PAUT TFM-FMC inspection on Plate Welds Line Joints for M/S PUNE Metro at India
· ECT/NFT/RFET/IRIS inspection on Exchanger Tubes for M/S Petro Vietnam shutdown at Vietnam
· PAUT inspection on HHPS Pipe Line Joints for M/S Petro Vietnam shutdown at Vietnam
· PAUT inspection on Dryer SS Plate for M/S Dow Chemical's Singapore Pte Ltd
· ECT/RFET/IRIS inspection of Heat exchanger tubes for M/s. Exxon Mobil Singapore
· ECT/RFET/IRIS inspection of Heat exchanger tubes for M/s. Singapore Refinery (SRC) Singapore
· LRUT-Inspection of plant piping & pipeline for M/s SRC Singapore
· SRUT Inspection of Tank Bottom Plate welds for M/s SRC Singapore
· LRUT-Inspection of plant piping & pipeline for M/S Petro Vietnam shutdown at Vietnam
· DRT-Inspection of plant piping & pipeline for M/s SRC Singapore
· ECT/RFET/IRIS inspection of Heat exchanger tubes for M/s. ORPIC, OMAN
· Phased array inspection on Piping welds Omani scan for M/s Samsung engineering / Fluor / Shah Gas Devolvement (SGD) U & O project, Abu Dhabi, UAE.
· ECT/IRIS inspection of Heat exchanger tubes for M/s. ADGAS, DAS-ISLAND, UAE
· RFET / IRIS inspection on Exchanger Tubes for M/S Petro Vietnam shutdown at Vietnam
· RFT/ ECT Inspection of Exchanger Tubes for BPCL Shutdown Dec 2013, Mumbai, India
· RFT/ ECT Inspection of Exchanger Tubes for RIL Hazira Shutdown Gujarath, India
· IRIS/ECT Inspection of Exchanger Tubes for HPCL-VR Vizag, India
· IRIS inspection on Boiler Bank Tubes for NTPC Talchar, Phase V (Sep-2014) India
· IRIS inspection on Boiler Bank Tubes for NTPC Talchar, Phase IV (Sep-2014) India
· IRIS inspection on Boiler Bank Tubes for NTPC Talchar, Phase I (July-2015) India
· IRIS inspection on Boiler Bank Tubes for NTPC Talchar, Phase II (Aug-2015) India
· IRIS inspection on Boiler Bank Tubes for NTPC Talchar, Phase III (Sep-2015) India
· RFET&IRIS inspection on Exchanger Tubes for HPCL Plant, Vizag, India
· NFT/RFT inspection of Exchangers for M/s. HMEL, Bhatinda
· LRUT-Health study of five Pipelines – Non-Destructive Testing (NDT) of five Pipelines for M/s Mumbai Port Trust
· Long Range UT of Crude pipelines, Insulated lines for M/s. RIL, Hazira
· LRUT-Inspection of plant piping & pipeline for M/s HPCL-Mumbai, Indiia
· LRUT using MsS of Pipeline system of plant for M/s VOPAK, Kandla
· Long Range UT of Buried and Culvert lines for M/s. RIL, Jamnagar
· Long Range UT of Offshore lines for M/s. Cairn India Ltd., Hazira
· LRUT-Inspection of plant piping & pipeline for M/s GAIL Dibiyapur
· LRUT-Inspection of plant piping & pipeline for M/s GAIL Jhabua
· Long Range UT of Stiffener lines for M/s. TISCO, Tatanagar.
· Long Range UT of Culvert lines, Ceramic Brick Insulated and PE wrapping lines for M/s. HPCL, Vizag.
· Long Range UT of Culvert lines for M/s. IOCL, Palem
· Long Range UT of Buried &Culvert lines, Flare header Lines for M/s. ONGC-HAZIRA
· Corrosion Mapping of Gas pipelines for GAIL using PAUT for contractor M/s/ TD Williams in KG Basin, Vadodara and VSPL Region, India.
· PMI Inspection of plant equipment in BORL, Bina, India.
· Long Range UT using Teletest of Buried lines, for M/s. HPCL-VR
· Long Range UT using MsS of Buried lines, for M/s. HPCL-VR
· Long Range UT of Risers, Pipe lines, for M/s. ONGC-Offshore-Mumbai
· Long Range UT of Risers, Pipe lines, for M/s. CAIRN-Offshore-Surath
· Long Range UT of Risers, Pipe lines, for M/s. SP-ARMADA& BUMI ARMADA-Mumbai
· MFL of out of service storage Tank floor inspection of tanks forJNPT MUMBAI
· LRUT-Inspection of plant piping & pipeline for M/s CAIRN INDIA LTD VIRAM GAM TERMINAL Gujrat, India
· LRUT-Inspection of plant piping & pipeline for M/s IOCL GUWAHATI, India.
· Phased array inspection on Piping welds Omaniscan for M/S Weels India limited
· IRIS inspection on Boiler Bank Tubes for Sarswati sugar mills lrd (may-jun-2017) India
· ECT inspection of Heat exchanger tubes for M/s. IFFCO-Paradeep
· Phased array inspection on Coke drum welds Omaniscan for IOCL Panipa
· Long Range UT of High Temperature lines for M/s. IOCL, Mathura
· LRUT of Column lines for M/s. RIL, Hazira
· LRUT-Inspection of plant piping & pipeline for M/s HPCL-Mumbai, India.
· Phased Array UT inspection of pipe welds for M/s. GAIL, Dibyapur.
· MFL of out of service storage Tank floor inspection of tanks for Vopak CRL terminal Pvt. Ltd., old kandla, Gujarat, India
· RFT/ECT/IRIS/RVI of Heat exchanger tubes for M/s. HPCL, Vizag, India
· RFT of Heat exchanger tubes for M/s. L &T Powai, Mumbai, India
· RFT/ECT of Heat exchanger tubes for M/s CPCL, Chennai, India
· RFT/ECT of Heat exchanger tubes for M/s MFCL, Manglore, India
· ASME Boiler and Pressure Vessel Code, Section V
· ASME Section VIII Div-1 & Div-2
· ASME Section II
· ASME B31.3, B31.1
· AWS D1.1
· API 1104, 510, 635, 570, 580, 934
· Advanced Ultrasonic Testing HIC (AUT HIC) using Accu Trak AUT of M/s AUT Solutions UK
· Long Range Ultrasonic Testing using Teletest - M/s Plant Integrity, UK., MSSR- South West Research Institute, Texas, GUL
· Phased Array UT - Omni scan MX, MX2, MX3 of M/s Olympus NDT, Canada, M2M Gekko Eddyfi, Sonatest Veo+
· Short Range UT-ISONIC-3510, SONOTRON NDT
· Ultrasonic Test – USM 36, Modosonic Einstein II, Epoch 650 Olympus, RMS Scanner , Scorpion Scanner Silvering
· ECT/ECA, Saturated ECT/IRIS/MFL/RFT/NFT - MS 5800 of M/s Olympus NDT, Multi scan ECTANE-II EDDIFI, Costar
· DRT – Reaytham GE Inspection
· Pulsed Eddy Current Testing - LYFT EDDIFI, MAXWEL
· Video scope inspection- IPLEX- Olympus
· Magnetic Flux Leakage Testing – SILVERVING VS2I, VS3I
· ARC-PMI Testing – Oxford Unit
· Assess equipment condition and report with repair recommendation based on code and procedural requirements.
· Carryout inspection of equipment in accordance with the specified plans and procedures.
· Review the NDT reports and findings and field verify as necessary.
· Selection of an appropriate inspection /NDT techniques as per codes/standards and specification.
· Carrying out in-service inspection of pressure vessels, heat exchangers, fin fan coolers, process piping systems, pipelines, and tanks to assure the mechanical integrity.
· Preparation of inspection reports /certificates with all findings, abnormalities, and recommendations.
· Planning and assigning NDT teams for day-to-day jobs.
· Allocation and Utilization making of NDT manpower.
· Coordinate with QA/QC and production personnel regarding schedule of NDT activities.
· Coordinate QC/NDT personnel Industrial qualification, Examination, Training and Renewals that are externally organized.
· Monitor the daily progress of ongoing production at work sites and, where necessary, intervene to resolve any NDT related issues.
· Planning, organizing, coordinating, and directing inspection, NDT, QA/QC activities towards company objectives of Quality Assurance and Quality Control
· As an Engineer-in-charge for various sites, co-ordinating with client and assigning personnel to specific jobs.
· Planning and executing day-to-day activities in sites as per the client requirements.
· Preparing NDT procedures for Advanced NDT techniques such as AUT, LRUT, IRIS, ECT, ECA, RFT, MFL, PAUT, TOFD, TFM_FMC, PCI, Pulsed ECT, SRUT, Arc-PMI, RT, UT, MT, PT, HT, FT
· Preparation and reviewing day-to-day inspection reports and submission of Final reports to client.
· Carrying out inspection of Heat exchanger tubes, Boilers, Air fin coolers, Shells, Piping
· Inspection of pipe and tube welds and corrosion monitoring of cross-country pipelines.
· Review project contract documents and identify the scope of work and execute job accordingly.
· Attending job specific technical meetings.
· Training personnel in Advanced NDT techniques.
· Maintaining Safety at sites and conducting toolbox talks at site.
· Preparing required documents for Auditing Works.
· Trained in Advanced Ultrasonic Testing HIC (AUT HIC) using Accu Trak AUT of M/s AUT Solutions UK
· Trained in Long Range Ultrasonic Testing using Teletest of M/s Plant Integrity, UK
· Trained in Long Range Ultrasonic Testing using MsS R 3030R of M/s Southwest Research Institute, Texas
· Trained in Long Range Ultrasonic Testing using GUL of Guided Ultrasonic Ltd, UK
· Trained in ECT/IRIS/MFL/RFT/NFT Training using MS 5800 of M/s Olympus NDT, Canada
· Trained in ECT/ECA/IRIS/MFL/RFT/NFT Training using Multi scan ECTANE-II EDDIFI, Canada
· Trained in DRT using Reathym GE Inspection Equipment
· Trained in PECT Training using LYFT EDDIFI, Canada
· Trained in Phased Array UT, TFM-FMC, PCI, AUBT, SRUT and TOFD using Omni scan MX, MX2, MX3 of M/s Olympus NDT, Canada, Gekko Edify
· Trained in Magnetic Flux Leakage Testing using Floor map & Hands scan of M/s silverwing, UK
· Trained in Scorpion B-Scan using Scorpion of M/S Silverwing, UK
· Trained in Arc-PMI using Oxford Unit of NDTS Singapore
· Trained in Surface ECT using Olympus Nortech-600, of Olympus NDT, Canada
· Passport Number: R2789556
· Date of Birth: 06/06/1991
· English
· Telugu
· Hindi